Concrete Screw S-CSA HEX 6X100/45/60 ZP
Download Sormat code 9640071317
ETA-approved 6/8/10 concrete screw for cracked and non-cracked concrete
- Self-tapping, approved screw anchors for push-through installations.
- Requires a small drill hole diameter. No prescribed tightening torque.
- No expansion forces allowing for small edge distances and spacings.
- Fully removable.
- ZP for dry indoor use.
Product overview
Other codes
/
Material
Steel, zinc plated
Packages
box (bag): 50 / outer carton: 250 / pallet: 14000
Weight
26.9 kg / 1000
Availability
end of life
Applications
- Facade scaffoldings
- Temporary fixings
- Seatings
- Shelves
- Cable racks
- Handrails
- Battens
Base materials
Approved for
- Cracked concrete
- Hollow-core slab
- Non-cracked concrete
Also suitable for
- Solid clay brick
- Solid sand-lime brick
Approvals / Certificates
Technical data
Installation details
Size
6
Length (L)
100
Thread (f)
70
Width across flats (SW)
11
Drive
T30
Max. fixture thickness (Tfix )
45/60
Installation details
Hole in fixture (Df)
9
Drill hole diameter (d0) ⌀
6
Minimum drill hole depth
65/50
Drill hole depth (h1)
65/50
Nominal setting depth (Hnom)
55/40
Installation torque (Tinst)
14
Head details
Head diameter ⌀
14,5
Performance data
Base material
|
ETA | Load type | Embedment depth (hnom) | Load direction | Load value |
---|---|---|---|---|---|
Non-cracked concrete C20/25 | Yes | NRec | 55 mm |
![]() |
4.5 kN |
Non-cracked concrete C20/25 | Yes | VRec | 55 mm |
![]() |
5.6 kN |
Cracked concrete C20/25 | Yes | NRec | 55 mm |
![]() |
2.1 kN |
Cracked concrete C20/25 | Yes | VRec | 55 mm |
![]() |
4.5 kN |
Non-cracked concrete C20/25 | Yes | NRec | 40 mm |
![]() |
1.4 kN |
Non-cracked concrete C20/25 | Yes | VRec | 40 mm |
![]() |
3.1 kN |
Cracked concrete C20/25 | Yes | NRec | 40 mm |
![]() |
1.4 kN |
Cracked concrete C20/25 | Yes | VRec | 40 mm |
![]() |
3.1 kN |
Hollow-core slab, bottom flange thickness 25 mm | Yes | NRec | 40 mm |
![]() |
0.5 kN |
Hollow-core slab, bottom flange thickness 25 mm | Yes | VRec | 40 mm |
![]() |
0.5 kN |
Hollow-core slab, bottom flange thickness 30 mm | Yes | NRec | 40 mm |
![]() |
1.0 kN |
Hollow-core slab, bottom flange thickness 30 mm | Yes | VRec | 40 mm |
![]() |
1.0 kN |
Hollow-core slab, bottom flange thickness 40 mm | Yes | NRec | 40 mm |
![]() |
1.4 kN |
Hollow-core slab, bottom flange thickness 40 mm | Yes | VRec | 40 mm |
![]() |
1.4 kN |